| Fernair
Distributors Pty Ltd |
|
 |
 |
PRODUCTS -
TECOAIR DUCTED SYSTEMS |
|
. |
Reverse
Cycle Ducted Air Conditioning by TECOAIR |
 |
|
 |
 |
 |
 |
| |
| |
| |
 |
|
|

 |
. |
TecoAir
Features
 |
|
Cooling
Mode |
|
The air
conditioner efficiently cools the room. |
 |
|
Heating
Mode |
|
The air
conditioner efficiently heats the room. |
 |
|
Fan
Only Mode |
|
Provides
air circulation and filtration without cooling or heating. |
 |
|
Dehumidifying
Mode |
|
Automatically
extracts excess moisture from the air. |
 |
|
Logic
Control |
|
Microprocessor
control of temperature changes in 256 combinations. |
 |
|
Auto
Change Over |
|
Set the
controller and let the unit select the mode to achieve the
desired temperature. |
 |
|
Fan
Speed Control |
|
3 Speed
fan control. Select fan speed to suit your comfort requirements. |
 |
|
Thermostat
Control |
|
Set
temperature range from 16°C to 31°C. |
 |
|
Scroll
Compressor |
|
The
quietest, smoothest operation available. |
 |
|
Defrosting
Function |
|
Automatically
operates when the outdoor section of the unit is iced or too
cold. |
 |
|
Timer
Control |
|
Set the
stop/start operation of the air conditioner for any period from
1 to 24 hours. |
 |
|
Sleep
Control |
|
Automatically
adjusts the room temperature for the best sleeping environment. |
 |
|
Restart
Protection |
|
Compressor
is protected from restarting for 3 minutes. |
 |
|
Infrared
Remote Controller |
|
Easy
control in the palm of your hand with LCD display. |
|
|
 |
|
|
|
. |
5
Year Residential
Have
piece of mind that your Teco product is covered by a 5 year
manufacturers warranty.
|
|
 |
|
|

 |
. |
5
Single and Three Phase Systems available
The
Teco range offers systems from 8.8kw to 18.2kw
Single
Phase Systems
Three Phase Systems
|
|
 |
|
|
TecoAir
Specifications - Model LE-LU30K1YAH - 3.5 HP (1 Ph) - 8800/9100 Watts
|
MODEL |
INDOOR |
OUTDOOR |
| LE3009H |
LU30K1YAH |
| Horse
Power Rating |
3.5 |
| Cooling
Capacity (kw) |
8.8 |
| Power
Consumption (kw) |
3.65 |
|
Running Current (A) |
16.0 |
| EER |
2.41 |
| Heating
Capacity (kw) |
9.1 |
| Power
Consumption (kw) |
3.35 |
|
Running
Current (A) |
14.8 |
|
COP |
2.72 |
| Protection
Devices |
Fuse
Relay |
| Refrigerant
Type |
R22 |
| Refrigerant
Piping (liquid & suction) |
3/8"
& 5/8" |
| Airflow
(indoor cooling/heating) |
570/570
(L/S) |
55
(CMM) |
| Sound
Pressure dB(A) |
- |
63.0 |
| Fan
Motor Output (w) |
315 |
120 |
| External
Static Pressure (Pa) |
110 |
- |
| Power
Supply |
1
Ph, 240V, 50Hz |
1
Ph, 240V, 50Hz |
| Unit
Dimensions |
W
(mm) |
990 |
900
(1,080) |
| (packed) |
D
(mm) |
610 |
300
(430) |
| |
H
(mm) |
392 |
640
(710) |
| Spigot
(Supply) |
W/H
(mm) |
245/260 |
- |
| Spigot
(Return) |
W/H
(mm) |
680/320 |
- |
| Weight
(packed) |
kg |
45 |
65
(75) |
| Condensate
Drain |
20mm
Diameter |
- |
1.
Specifications are subject to change without notice for future product
improvement.
2. Cooling Rating conditions: Indoor 27°C DB, 19°C WB; Outdoor 35°C
DB, 24°C WB; Refrigerant piping length (one way): 5m. Tested voltage:
240V & 415V.
3. Heating Rating conditions: Indoor 20°C DB; Outdoor 7°C DB, 6°C
WB; Refrigerant piping length (one way): 5m. Tested voltage: 240V
& 415V. |
|


|
|
|
TecoAir
Specifications - Model LE-LU38K1YAH - 4.5 HP (1 Ph) - 10600/10800 Watts
|
MODEL |
INDOOR |
OUTDOOR |
| LE3811H |
LU38K1YAH |
| Horse
Power Rating |
4.5 |
| Cooling
Capacity (kw) |
10.6 |
| Power
Consumption (kw) |
3.78 |
|
Running Current (A) |
17.0 |
| EER |
2.80 |
| Heating
Capacity (kw) |
10.8 |
| Power
Consumption (kw) |
3.97 |
|
Running
Current (A) |
16.5 |
|
COP |
2.72 |
| Protection
Devices |
Internal
thermostat, HP switch |
| Refrigerant
Type |
R22 |
| Refrigerant
Piping (liquid & suction) |
1/2"
& 3/4" |
| Airflow
(indoor cooling/heating) |
570/570
(L/S) |
55
(CMM) |
| Sound
Pressure dB(A) |
- |
68.0 |
| Fan
Motor Output (w) |
315 |
150 |
| External
Static Pressure (Pa) |
110 |
- |
| Power
Supply |
1
Ph, 240V, 50Hz |
1
Ph, 240V, 50Hz |
| Unit
Dimensions |
W
(mm) |
990 |
950
(1,013) |
| (packed) |
D
(mm) |
610 |
350
(463) |
| |
H
(mm) |
392 |
900
(1011) |
| Spigot
(Supply) |
W/H
(mm) |
245/260 |
- |
| Spigot
(Return) |
W/H
(mm) |
680/320 |
- |
| Weight
(packed) |
kg |
45 |
87
(95) |
| Condensate
Drain |
20mm
Diameter |
- |
1.
Specifications are subject to change without notice for future product
improvement.
2. Cooling Rating conditions: Indoor 27°C DB, 19°C WB; Outdoor 35°C
DB, 24°C WB; Refrigerant piping length (one way): 5m. Tested voltage:
240V & 415V.
3. Heating Rating conditions: Indoor 20°C DB; Outdoor 7°C DB, 6°C
WB; Refrigerant piping length (one way): 5m. Tested voltage: 240V
& 415V. |
|


|
|
|
TecoAir
Specifications - Model LE-LU38K1MAH - 4.5 HP - 10600/10800 Watts
|
MODEL |
INDOOR
|
OUTDOOR |
| LE3811H
|
LU38K1MAH |
| Horse
Power Rating |
4.5 |
| Cooling
Capacity (kw) |
10.6 |
|
Running Current (A) |
7.0 |
| EER |
2.67 |
| Heating
Capacity (kw) |
10.8 |
| Power
Consumption (kw) |
4.23 |
|
Running
Current (A) |
6.5 |
|
COP |
2.55 |
| Protection
Devices |
Internal
thermostat, HP switch |
| Crankcase
Heater (w) |
80 |
| Refrigerant
Type |
R22 |
| Refrigerant
Piping (liquid & suction) |
1/2"
& 3/4" |
| Airflow
(indoor cooling/heating) |
570/570
(L/S) |
55
(CMM) |
| Sound
Pressure dB(A) |
- |
68.0 |
| Fan
Motor Output (w) |
315 |
150 |
| External
Static Pressure (Pa) |
110 |
- |
| Power
Supply |
1
Ph, 240V, 50Hz |
3
Ph, 415V, 50Hz |
| Unit
Dimensions |
W
(mm) |
990 |
950
(1,013) |
| (packed) |
D
(mm) |
610 |
350
(463) |
| |
H
(mm) |
392 |
900
(1011) |
| Spigot
(Supply) |
W/H
(mm) |
245/260 |
- |
| Spigot
(Return) |
W/H
(mm) |
950/320 |
- |
| Weight
(packed) |
kg |
45 |
87
(95) |
| Condensate
Drain |
20mm
Diameter |
- |
1.
Specifications are subject to change without notice for future product
improvement.
2. Cooling Rating conditions: Indoor 27°C DB, 19°C WB; Outdoor 35°C
DB, 24°C WB; Refrigerant piping length (one way): 5m. Tested voltage:
240V & 415V.
3. Heating Rating conditions: Indoor 20°C DB; Outdoor 7°C DB, 6°C
WB; Refrigerant piping length (one way): 5m. Tested voltage: 240V
& 415V. |
|


|
|
|
TecoAir
Specifications - Model LE-LU60K1MAH - 6 HP - 15200/16700 Watts
|
MODEL |
INDOOR |
OUTDOOR |
| LE6016H |
LU60K1MAH |
| Horse
Power Rating |
6.0 |
| Cooling
Capacity (kw) |
15.2 |
| Power
Consumption (kw) |
6.0 |
|
Running Current (A) |
9.6 |
| EER |
2.53 |
| Heating
Capacity (kw) |
16.7 |
| Power
Consumption (kw) |
5.9 |
|
Running
Current (A) |
10.8 |
|
COP |
2.83 |
| Protection
Devices |
Internal
thermostat, HP switch |
| Crankcase
Heater (w) |
80 |
| Refrigerant
Type |
R22 |
| Refrigerant
Piping (liquid & suction) |
1/2"
& 3/4" |
| Airflow
(indoor cooling/heating) |
815/820
(L/S) |
110
(CMM) |
| Sound
Pressure dB(A) |
- |
70.0 |
| Fan
Motor Output (w) |
425 |
150 |
| External
Static Pressure (Pa) |
160 |
- |
| Power
Supply |
1
Ph, 240V, 50Hz |
3
Ph, 415V, 50Hz |
| Unit
Dimensions |
W
(mm) |
1,260 |
950
(1,013) |
| (packed) |
D
(mm) |
610 |
350
(463) |
| |
H
(mm) |
392 |
1,370
(1,481) |
| Spigot
(Supply) |
W/H
(mm) |
710/300 |
- |
| Spigot
(Return) |
W/H
(mm) |
950/320 |
- |
| Weight
(packed) |
kg |
60 |
118
(127) |
| Condensate
Drain |
20mm
Diameter |
- |
1.
Specifications are subject to change without notice for future product
improvement.
2. Cooling Rating conditions: Indoor 27°C DB, 19°C WB; Outdoor 35°C
DB, 24°C WB; Refrigerant piping length (one way): 5m. Tested voltage:
240V & 415V.
3. Heating Rating conditions: Indoor 20°C DB; Outdoor 7°C DB, 6°C
WB; Refrigerant piping length (one way): 5m. Tested voltage: 240V
& 415V. |
|
|

 |
|
TecoAir
Specifications - Model LE-LU70K1MAH - 7 HP - 18200/19200 Watts
|
MODEL |
INDOOR |
OUTDOOR |
| LE7019H |
LU70K1MAH |
| Horse
Power Rating |
7.0 |
| Cooling
Capacity (kw) |
18.2 |
| Power
Consumption (kw) |
7.2 |
|
Running Current (A) |
12.7 |
| EER |
2.53 |
| Heating
Capacity (kw) |
19.2 |
| Power
Consumption (kw) |
7.0 |
|
Running
Current (A) |
12.5 |
|
COP |
2.74 |
| Protection
Devices |
Internal
thermostat, HP switch |
| Crankcase
Heater (w) |
80 |
| Refrigerant
Type |
R22 |
| Refrigerant
Piping (liquid & suction) |
1/2"
& 3/4" |
| Airflow
(indoor cooling/heating) |
980/990
(L/S) |
110
(CMM) |
| Sound
Pressure dB(A) |
- |
72.0 |
| Fan
Motor Output (w) |
600 |
2
x 90 |
| External
Static Pressure (Pa) |
160 |
- |
| Power
Supply |
1
Ph, 240V, 50Hz |
3
Ph, 415V, 50Hz |
| Unit
Dimensions |
W
(mm) |
1,410 |
950
(1,013) |
| (packed) |
D
(mm) |
610 |
350
(463) |
| |
H
(mm) |
392 |
1,370
(1,481) |
| Spigot
(Supply) |
W/H
(mm) |
710/300 |
- |
| Spigot
(Return) |
W/H
(mm) |
1100/320 |
- |
| Weight
(packed) |
kg |
70 |
120
(129) |
| Condensate
Drain |
20mm
Diameter |
- |
1.
Specifications are subject to change without notice for future product
improvement.
2. Cooling Rating conditions: Indoor 27°C DB, 19°C WB; Outdoor 35°C
DB, 24°C WB; Refrigerant piping length (one way): 5m. Tested voltage:
240V & 415V.
3. Heating Rating conditions: Indoor 20°C DB; Outdoor 7°C DB, 6°C
WB; Refrigerant piping length (one way): 5m. Tested voltage: 240V
& 415V. |
|
|


|