ACTRON AIR THREE PHASE

.

What a range ! 7 systems between 12.6kw and 25.2kw

 

A massive product range allows us to select the exact size to suit your application.

Tech Specs - Three Phase
OUTDOOR MODEL
INDOOR MODEL
  SRA12C
SRA13E
SRA14C
SRA14E
SRA16C
SRA16E
SRA18C
SRA18E
SRA20C
SRA20E
SRA22C
SRA22E
SRA25C
SRA25E
*Nominal Capacity (kw)   12.6 14.1 16.0 18.3 19.1 21.6 25.2
Net Capacity A.S. 3823 (kw) Cooling 11.0 13.2 14.0 16.0 16.7 18.9 22.1
  Heating 11.9 14.2 15.1 17.3 18 20.4 23.8
Input Power(kw) Cooling 4.1 4.8 5.0 6.0 6.2 6.9 8.1
  Heating 3.99 4.64 5.0 5.56 5.88 6.49 7.7
** EER Cooling 2.7 2.7 2.8 2.67 2.7 2.7 2.7
**COP Heating 2.98 2.95 3.1 3.1 3.06 3.14 3.09
Star Rating Cooling
  Heating
POWER SUPPLY -50 HZ 415 Volts x 3 Phase
Full Load Amps Phase 1 11.6 14 14.8 16.3 17.5 20 23.3
  Phase 2 & 3 7.5 9.1 9.6 10.5 11.3 13.0 15.2
COMPRESSOR TYPE SCROLL
Airflow Indoor (L/s) Maximum 730.0 820.0 920.0 1040.0 1100.0 1250.0 1460.0
  Nominal 630.0 710.0 800.0 900.0 960.0 1080.0 1270.0
  Minimum 550 620 700.0 780 830 940 1100
OUTDOOR DIMENSIONS (mm) Depth 500 580 580 630
  Height 900 990 990 1175
  Width 1190 1320 1460 1570
INDOOR DIMENSIONS (mm) Depth 615 615 695
  Height 412 412 485
  Width 1090 1190 1290 1470
WEIGHTS NOMINAL (kg) Outdoor unit 106 140 145.0 150 160 170 220
  Indoor Unit 55 60 60.0 65 70 85 95
***SOUND PRESSURE dB(A) Outdoor unit 49 49 49 50 51 54 60
ActronAir Controllers M Series 24 Hour STD STD STD STD STD STD STD
  M Series 7Day OPT OPT OPT OPT OPT OPT OPT

Important – The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop. Please check prior to purchase.

(1) Nominal Capacity (kW) relates to the compressor capacity. (Heating includes input power)
Design Conditions - Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB.
Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB.
Operating Conditions - Cooling: 15°C DB to 50°C DB Outdoor / Air Entering Indoor 29°C DB.
Heating: –5°C to 21°C DB Outdoor / Air Entering Indoor 21°C DB.
(2) EER = Energy Efficiency Ratio (Nett Capacity Cooling ÷ Input Power Cooling)
(3) COP = Coefficient Of Performance (Nett Capacity Heating ÷ Input Power Heating)
(4) Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Results are based on outdoor conditions over a hard reflecting surface for the ground plane only, with no walls or other obstructions nearby. Two values provided: one at low speed outdoor fan and one at high speed outdoor fan. Sound levels may vary in different locations and surroundings.
(5) Sound Power Levels are measured in accordance with the requirements of the Department of Environment and Conservation (NSW) under the Australian Environment Council 'Technical Basis for the Regulation of Noise Labelling of New Air Conditioners in Australia'. The measurement procedures contained in this regulation are equivalent to Australian Standard AS1217.2 'Acoustics – Determination of Sound Power Levels of Noise Sources Part 2 – Precision Methods for Broad-Band Sources in Reverberation Rooms'.
Specifications subject to change without notice.