ACTRON AIR SINGLE PHASE

.

Innovation ! - Single Phase available to 18.3kw 

 

The three largest units in the single phase product offer nominal capacities of 12.6 - 16.0 and 18.3kw respectively. No other manufacturer can offer such flexibility. The larger single phase units are fitted with Actron's SureStart soft starter to ensure compliance with the NSW Electrical Service Regulations, ( confirm suitability with Supply Authority)

Tech Specs - Single Phase

OUTDOOR MODEL
INDOOR MODEL
SRE07C
SRA07E
SRE09C
SRA09E
SRA11C
SRA11E
SRA13C
SRA13E
SRA15C
SRA16E
SRA17C
SRA17E
*Nominal Capacity (kw) 7.6 9.6 11.1 12.6 16.0 18.3
Net Capacity kW A.S. 3823 - Cooling 6.6 8.4 9.7 11.0 15.0 16.8
Net Capacity kW A.S. 3823 7.2 9.1 10.5 11.9 15.9 17.9
Input Power Cooling(kw) 2.5 3.2 3.7 4.1 5.3 5.7
Input Power Heating(kw) 2.45 3.05 3.51 3.85 4.7 5.25
** EER(Cooling) 2.6 2.7 2.7 2.7 2.9 3.0
**COP(Heatimg) 2.91 2.98 2.97 3.09 3.4 3.41
Star Rating - Cooling
Star Rating - Heating
POWER SUPPLY -50 hz 240 Volts X 1 Phase
Full Load Amps - Phase1 15.9 19.8 23.2 25 31.8 37.5
COMPRESSOR TYPE SCROLL
Airflow Indoor (l/s) 440 560 640 730 920 1040
Nominal Airflow 380.0 480.0 560.0 630.0 800.0 900.0
Minimum Airflow 330 420 480 550 700.0 780
DIMENSIONS NOMINAL
Outdoor -
Depth mm
375 500 580
Height mm      800 900 990
Width - mm    1080 1190 1320
Indoor-
Depth mm
615 615 615
Height 412 412 412
Width 860 1090 1190 1290
WEIGHTS NOMINAL (kg)
Outdoor unit 80 85 90 107 145.0 150
Indoor Unit 40 45 50 55 60.0 65
***SOUND PRESSURE LEVEL
Outdoor unit dB(A) 51 51 52 49 49.0 50
Suitability with ActronAir Digital Controllers
M Series 24 Hour STD STD STD STD STD STD
M Series 7 Day OPT OPT OPT OPT OPT OPT
STD = Supplied Standard with purchase of the unit. OPT = Can be bought as an Optional extra.

Specifications are nominal and subject to change without notice. Please check prior to purchase.
* Nominal kW relates to the compressor capacity.
Design Conditions – Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB. Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB.
Operating Conditions - Cooling: 15°C DB to 50°C DB Outdoor / Air Entering Indoor 29°C DB. Heating: -5°C to 21°C DB Outdoor / Air Entering Indoor 21°C DB.
** EER = Energy Efficiency Ratio (Nett Capacity Cooling ? Input Power Cooling)
** COP = Coefficient Of Performance (Nett Capacity Heating ÷ Input Power Heating)
*** Sound Pressure Levels measured at a distance of 2m. Sound levels may vary in different locations and surroundings.
Important: The Local Electricity Supply Authority may require limits on - starting current, running current and voltage drop. Please check prior to purchase.