ACTRON AIR ESP - DIGITAL

.

The most comfortable air conditioning money can buy. 

 

Released in September 2005 after years of development and testing - the revolution has began - we'll never look at air conditioning the same again.

Tech Specs - ESP
OUTDOOR MODEL
INDOOR MODEL
  SRD13C
SRD13E
SRD15C
SRD15E
SRD20C
SRD20E
SRD22C
SRD22E
1Nominal Capacity (kw) Heating 13.70 17.13 20.17 22.81
Cooling 13.09 16.37 19.27 21.79
Net Capacity (kw)
AS/NZS 3823.1.2
Cooling (min - max) 11.85 (1.19 - 11.85) 15.00 (1.50 - 15.00) 17.20 (1.72 – 17.20) 19.40 (1.94 – 19.40)
Heating (min - max) (min - max) 12.82 (2.44 - 12.82) 15.90 (3.02 - 15.90) 18.85 (3.85 – 18.85) 20.91 (3.97 – 20.91)
Input Power(kw) Cooling 4.27 5.25 6.18 6.89
Heating 3.91 4.74 5.89 6.49
2EER Cooling 2.77 2.86 2.83 2.81
3COP Heating 3.28 3.35 3.21 3.22
Star Rating Cooling
Heating
Electrical
POWER SUPPLY -50 Hz Outdoor 240 Volts X 1 Phase 415 Volts x 3 Phase
Indoor 240 Volts X 1 Phase
Rated Amps (AS/NZS 3823.1.2) 21.6 26.1 14.2 16.2
Circuit Breaker Amps 32 32 20 20
Compressor
Compressor Type Digital Scroll
Starting Method Soft Start Soft Start - -
Airflow
Airflow Indoor (l/s)Nominal @ 150 Pa Maximum 760 920 1100 1250
Nominal 650 800 960 1080
Minimum 560 700 830 940
Dimensions
Outdoor Dimensions Nominal (mm) Depth 500 580 580 580
Height 900 990 990 990
Width 1190 1320 1320 1460
Indoor Dimensions Nominal (mm) Depth 620 645 620 695
Height 412 412 412 485
Width 1100 1190 1300 1470
Weights Nominal (kg) Outdoor 117 151 161 171
Indoor 55 60 70 85
Sound Pressure Level
4 Outdoor Unit dB(A) (Low / High Fan) 47/50 49/52 50/53 51/53
Sound Power Level
5Outdoor Unit dB(A) (Low / High Fan) 64/67 66/69 67/69 68/70
Refrigeration System
Refrigerant R22 R22 R22 R22
Suitability with ActronAir Digital Controllers
M Series 24 Hour Yes Yes Yes Yes
M Series 7 Day Yes Yes Yes Yes
C Series / D Series / Manual Inputs N/A N/A N/A N/A

Important – The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop. Please check prior to purchase.
(1) Nominal Capacity (kW) relates to the compressor capacity. (Heating includes input power) Design Conditions - Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB.
Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB.
Operating Conditions - Cooling: 15°C DB to 50°C DB Outdoor / Air Entering Indoor 29°C DB.
Heating: –5°C to 21°C DB Outdoor / Air Entering Indoor 21°C DB.

(2) EER = Energy Efficiency Ratio (Nett Capacity Cooling ÷ Input Power Cooling)

(3) COP = Coefficient Of Performance (Nett Capacity Heating ÷ Input Power Heating)

(4) Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Results are based on outdoor conditions over a hard reflecting surface for the ground plane only, with no walls or other obstructions nearby. Two values provided: one at low speed outdoor fan and one at high speed outdoor fan. Sound levels may vary in different locations and surroundings.

(5) Sound Power Levels are measured in accordance with the requirements of the Department of Environment and Conservation (NSW) under the Australian Environment Council 'Technical Basis for the Regulation of Noise Labelling of New Air Conditioners in Australia'. The measurement procedures contained in this regulation are equivalent to Australian Standard AS1217.2 'Acoustics – Determination of Sound Power Levels of Noise Sources Part 2 – Precision Methods for Broad-Band Sources in Reverberation Rooms'.

Specifications subject to change without notice.